ISO IEC 11801 pdf download – lnformation technology – Generic cabling for customer premises Amendment 2 (2010) CORRIGENDU M1

admin
ISO IEC 11801 pdf download – lnformation technology – Generic cabling for customer premises Amendment 2 (2010) CORRIGENDU M1

ISO IEC 11801 pdf download – lnformation technology – Generic cabling for customer premises Amendment 2 (2010) CORRIGENDU M1
Corrigendum 1 applies to Amendment 2(2010) of lSO/IEC 11801:2002.2Normative references
Replace the existing references by the following:
IEC 60603-7-2:2010,Connectors for electronic equipment – Part 7-2: Detail specification for8-way,unshielded, free and fixed connectors, for data transmissions with frequencies up to100 MHz
IEC 60603-7-3:2010,Connectors for electronic equipment – Part 7-3: Detail specification for8-way,shielded, free and fixed connectors,for data transmissions with frequencies up to100 MHz
IEC 60603-7-4:2010,Connectors for electronic equipment – Part 7-4: Detail specification for8-way,unshielded, free and fixed connectors,for data transmissions with frequencies up to250 MHz
IEC 60603-7-5;2010,Connectors for electronic equipment – Part 7-5: Detail specification for8-way,shielded, free and fixed connectors,for data transmissions with frequencies up to250 MHz
IEC 60603-7-41:2010,Connectors for electronic equipment – Part 7-41:Detail specificationfor 8-way,unshielded, free and fixed connectors, for data transmissions with frequencies upto 500 MHz
IEC 60603-7-51:2010, Connectors for electronic equipment – Part 7-51: Detail specificationfor 8-way,shielded, free and fixed connectors, for data transmissions with frequencies up to500 MHz
IEC 61156-2:2010,Multicore and symmetrical pair/lquad cables for digital communications -Part 2: Symmetrical pair/quad cables with transmission characteristics up to 100 MHz -Horizontal floor cable – sectional specification
IEC 61156-6;2010,Multicore and symmetrical pairlquad cables for digital communications -Part 6: Symmetrical pairlquad cables with transmission characteristics up to 1 000 MHz -Work area wiring – sectional specification
lnsert the following reference:
ISO/IEC 14763-1,Information technology – lmplementation and operation of customerpremises cabling – Part 1 : Administration
5.7.5.1General requirements
Replace the second sentence as follows:
Until ISOIEC 14763-2ispublished, relevant information can be foundinISO/IEC TR14763-2.
6.4.9 current carrying capacity
Replace the existing first paragraph by the following paragraph and Table:
The minimum current carrying capacity for channels of Classes D,E,EA, F and FA shall be inaccordance with Table 84.This shall be achieved by an appropriate design.