IEC 61865 pdf download – OVERHEAD LINES – CALCULATION OF THE ELECTRICAL COMPONENT OF DISTANCE BETWEEN LIVE PARTS AND OBSTACLES – METHOD OF CALCULATION
1 Scope
This International Standard provides guidance for the calculation of electrical distances between live and earthed parts required to prevent air-gap breakdown which may endanger members of the public who legitimately come close to live parts. It is applicable only to overhead lines designed to operate at more than 45 kV phase-to-phase a.c. It deals with the electrical component of distances between conductors and movable objects – vehicles on the ground, vessels on water, persons on top of objects or on the ground, wildlife on the ground (but not airborne), etc. This standard does not deal with the following public and worker safety aspects:
• stationary objects – structures beneath or next to lines, trees, ground contours, etc. These, in general, require consideration as to whether the structure can be climbed on, the extent to which the tree will grow, etc;
• minimum approach distance for live working, which is dealt with in IEC 61 472;
• capacitive coupling or magnetic induction by overhead lines, such as voltages induced in vehicles under a line, or in pipelines buried alongside it;
• currents flowing in the ground that originate from lines and result in step and touch voltages around structures during line faults or lightning strikes;
• flashover of line insulators or spark gaps, or a phase-to-phase discharge, resulting in audible and electrical noise and intense arcs;
• dielectric breakdown of the air between the conductors and the ground due to large fires beneath conductors;
• minimum electrical distances required to prevent discharge to adjacent overhead power or communication circuits.
This standard does not give the electrical distance requirements for the design of overhead line structures. Neither does it give the distance requirements for overhead line structures which need to be accessible to workers while the line is energized (for example, distances to line workers or painters). Distances between conductors and the structure of the tower are normally chosen to meet the required operating reliability of the line. It is possible that this distance may not always be adequate to allow live working or, in some cases, access for workers to parts of the structure near to live conductors.
2Normative references
The following normative documents contain provisions which, through reference in this text,constitute provisions of this International ‘Standard. For dated references,subsequentamendments to,or revisions of,any of these publications do not apply. However,parties toagreements based on this International Standard are encouraged to investigate the possibilityof applying the most recent editions of the normative documents indicated below.For undatedreferences, the latest edition of the normative document referred to applies.Members of lECand lso maintain registers of currently valid lnternational Standards.
IEC 60050(601):1985,International Electrotechnical Vocabulary (EV) – Chapter 601:Generation,transmission and distribution of electricity – General
IEC 60050(604):1987,International Electrotechnical Vocabulary (IEV) – Chapter 604:Generation, transmission and distribution of electricity – Operation
IEC 60060-1:1989,High-voltage test techniques – Part 1: General definitions and testrequirements
IEC 60071-1:1993, Insulation co-ordination – Part 1 : Definitions, principles and rulesIEC 60071-2:1996,Insulation co-ordination – Part 2: Application guide
IEC 61472:1998,Live working – Minimum approach distances – Method of calculation
3Terms, definitions and symbols
For the purposes of this International Standard, certain definitions from lEC 60050(601) andIEC 6o05o(6o4) as well as the following definitions apply.
3.1Definitions
3.1.1
nominal voltage of a system
suitable approximate value of voltage used to designate or identify a system[IEV 601-0i-21]
NOTE See also lEv 601-01-29: phase-to-phase voltage.
3.1.2
highest voltage of a system Us
highest value of operating voltage which occurs under normal operating conditions at any timeand any point in the system
[IEV 601-01-23]
NOTE 1 See also IEV 601-01-29: phase-to-phase voltage.
NOTE2Transient overvoltages due,for example,to switching operations and abnormal operation, as well asabnormal temporary variations of voltage, are not taken into account.
IEC 61865 pdf download – OVERHEAD LINES – CALCULATION OF THE ELECTRICAL COMPONENT OF DISTANCE BETWEEN LIVE PARTS AND OBSTACLES – METHOD OF CALCULATION
